SINTEF STF25 F95010
Test Programme F3 - Confined Jet and Pool Fires - Technical Report for Test PF2A
BFETS Phase 2
FABIG Members: Log-in to access all FABIG resources LOG IN
SUMMARY
SINTEF Energy - Norwegian Fire Research Laboratory (NBL) has the task to carry out a series of fire tests with confined jet and pool fires, according to the test programme F3 of Blast and Fire Engineering for Topside Structures. This report is for pool fire test PF2A.
The pool fire test PF2A represents a 6 m2 pool fire of condensate (a liquid fraction from an oil refinery) on a water bed in a 135 m3 enclosure.
The general fire behaviour such as flame geometry and characteristics, temperature field and heat load from this naturally ventilated fire was studied. The main purpose of PF2A was to investigate the difference in burning rate for fuel on a water bed compared to fuel directly on steel substrate (PF3).
The fuel burning rate was ~0.22 kg/s. The ventilation opening was 2.0 x 2.5 m (5.0 m2) as in jet fire JF1B. The fire was slightly under-ventilated, with a variation of average equivalence ratio of 0.85±0.29.
This technical report includes description of the test rig, the experimental details and a set of curves
from the measured parameters.
Online purchase options:
Non-Members of FABIG are able to purchase PDF copies of the reports.